Refine
Year of publication
Document type
- Article (peer-reviewed) (52)
- Contribution to a Periodical (13)
- Conference Proceeding (11)
- Part of a Book (4)
- Report (3)
- Diploma Thesis (1)
- Doctoral Thesis (1)
Keywords
- Encapsulation (6)
- Light-addressing (3)
- Parylene C (3)
- Amorphous silicon (2)
- Atomic layer deposition (ALD) (2)
- Microelectrode array (2)
- Osseointegration (2)
- Parylene (2)
- Sub-mm electrode chip (2)
- Substrates (2)
- Surface treatment (2)
- ALD (1)
- Action potential (1)
- Active MEA (1)
- Active implant (1)
- Adhesion (1)
- Adhesion measurement (1)
- Adhesives (1)
- Al2O3−TiO2 nanolaminates (1)
- Anti-biofilm coating (1)
- Antimicrobial coating (1)
- Atomic force microscope (1)
- Atomic layer deposition (1)
- Atomic-layer deposition (ALD) (1)
- Automation (1)
- Bellow (1)
- Bioamplifier (1)
- Biocompatible (1)
- Biocompatible and reprocessable (1)
- Biological system modeling (1)
- Biomaterial cell interactions (1)
- CD-ROM (1)
- CFR PEEK (1)
- CMOS‐MEAs (1)
- Cardiomyocyte (1)
- Cell tests (1)
- Chip in foil (1)
- Chip-film patch (1)
- Chitosan (1)
- Cross cut test (1)
- DLC PECVD (1)
- Die assembly (1)
- Die embedding (1)
- Dielectric strength (1)
- Distractor (1)
- Electron beam induced deposition (1)
- Electrophysiological recording (1)
- Electrophysiology, (1)
- Flexible microelectrode arrays (Flex-MEAs) (1)
- Fluorocarbon (1)
- Formazin (1)
- HFC (1)
- Heart failure (1)
- High voltage insulation layers (1)
- High-throughput screening (1)
- Hybrid Layers (1)
- Impedance spectroscopy (1)
- Implant (1)
- Implants (1)
- In-situ monitoring (1)
- Insulation (1)
- Ion channel (1)
- Iridium oxide (1)
- Latex (1)
- Layers (1)
- Local gas injection (1)
- Loose patch (1)
- Low-frequency noise (1)
- MEMS (1)
- Medical devices (1)
- Mesomanufacturing (1)
- Micro electrode arrays (1)
- Micro manipulator (1)
- Micro- and nanotechnology (1)
- Micro-implants (1)
- Microelectrode chip (1)
- Minimal invasive surgery (1)
- Model (1)
- Mouse (1)
- Myocardial Infarction (1)
- Nanostencil (1)
- Nephelometer (1)
- Nephelometric turbidimeter (1)
- Neuron (1)
- PCB (1)
- PE-ALD (1)
- PVD (1)
- Passivation (1)
- Patchclamping (1)
- Peel test (1)
- Piezoelectric actuator (1)
- Plasma (1)
- Plasma enhanced atomic layer deposition (PEALD) (1)
- Plasma etching (1)
- Plasma-enhanced atomic layer deposition (1)
- Polycrystalline silicon (1)
- Polyetheretherketone (PEEK) (1)
- Polyimide (1)
- Polyimide PI-2611 (1)
- Polyimides (1)
- Polyisoprene (1)
- Polymers (1)
- Porous silicon (1)
- Poster (1)
- Poster presentation (1)
- Printed circuit board (1)
- Printing (1)
- Scratch test (1)
- Semiconductor device modeling (1)
- Shadow mask (1)
- Shape (1)
- Signal pre-processing (1)
- Silicon (1)
- Spinal cages (1)
- Standardization (1)
- Stretchability (1)
- Substrate integrated electrodes (1)
- Substrate integrated microelectrodes (1)
- Surface modification of biomaterials (1)
- Surface roughness (1)
- Thin film coating (1)
- Thin-film microelectrodes (1)
- Titanium dioxide (1)
- Turbidity sensing (1)
- UV-Crosslinker (1)
- Water monitoring (1)
Course of studies
Wirtschaftliches Testverfahren zur Bestimmung der Wasserdampf-Durchlässigkeit von Kunststoff-Folien
(2018)
Schnittstelle für das Gehirn
(2020)
This work gives the theoretical background which is needed to understand what self-assembling monolayers are, how they work, how and for what they can be used. A closer look is taken on the possibility to create an area selective atomic layer deposition process. In a practical experiment the foundation for this process is laid. Therefor a silicon wafer is coated with gold using a evaporation process. The gold samples are exposed to the SAMs solution to grow them. Contact angle measurements as well as Fourier transform Infrared spectroscopy are used to check the existence of SAMs on the gold samples. Also there is investigated if different exposure times make any differences.