Refine
Year of publication
Document type
- Article (peer-reviewed) (52) (remove)
Is part of the Bibliography
- Yes (52)
Keywords
- Encapsulation (5)
- Light-addressing (3)
- Parylene C (3)
- Amorphous silicon (2)
- Atomic layer deposition (ALD) (2)
- Microelectrode array (2)
- Osseointegration (2)
- Parylene (2)
- Sub-mm electrode chip (2)
- ALD (1)
- Action potential (1)
- Active implant (1)
- Adhesion (1)
- Adhesion measurement (1)
- Adhesives (1)
- Al2O3−TiO2 nanolaminates (1)
- Anti-biofilm coating (1)
- Antimicrobial coating (1)
- Atomic force microscope (1)
- Atomic-layer deposition (ALD) (1)
- Automation (1)
- Bellow (1)
- Biocompatible (1)
- Biocompatible and reprocessable (1)
- CFR PEEK (1)
- Cardiomyocyte (1)
- Cell tests (1)
- Chip-film patch (1)
- Chitosan (1)
- Cross cut test (1)
- DLC PECVD (1)
- Die assembly (1)
- Die embedding (1)
- Dielectric strength (1)
- Distractor (1)
- Electron beam induced deposition (1)
- Electrophysiological recording (1)
- Electrophysiology, (1)
- Flexible microelectrode arrays (Flex-MEAs) (1)
- Fluorocarbon (1)
- Formazin (1)
- HFC (1)
- Heart failure (1)
- High voltage insulation layers (1)
- High-throughput screening (1)
- Hybrid Layers (1)
- Impedance spectroscopy (1)
- Implant (1)
- Implants (1)
- In-situ monitoring (1)
- Insulation (1)
- Ion channel (1)
- Iridium oxide (1)
- Latex (1)
- Layers (1)
- Local gas injection (1)
- Loose patch (1)
- Medical devices (1)
- Micro electrode arrays (1)
- Micro manipulator (1)
- Micro-implants (1)
- Microelectrode chip (1)
- Minimal invasive surgery (1)
- Model (1)
- Mouse (1)
- Myocardial Infarction (1)
- Nanostencil (1)
- Nephelometer (1)
- Nephelometric turbidimeter (1)
- Neuron (1)
- PCB (1)
- PE-ALD (1)
- PVD (1)
- Passivation (1)
- Patchclamping (1)
- Peel test (1)
- Piezoelectric actuator (1)
- Plasma (1)
- Plasma enhanced atomic layer deposition (PEALD) (1)
- Plasma etching (1)
- Plasma-enhanced atomic layer deposition (1)
- Polycrystalline silicon (1)
- Polyetheretherketone (PEEK) (1)
- Polyimide (1)
- Polyimide PI-2611 (1)
- Polyisoprene (1)
- Polymers (1)
- Porous silicon (1)
- Printed circuit board (1)
- Printing (1)
- Scratch test (1)
- Shadow mask (1)
- Spinal cages (1)
- Standardization (1)
- Stretchability (1)
- Substrate integrated electrodes (1)
- Substrate integrated microelectrodes (1)
- Substrates (1)
- Surface roughness (1)
- Surface treatment (1)
- Thin film coating (1)
- Thin-film microelectrodes (1)
- Titanium dioxide (1)
- Turbidity sensing (1)
- UV-Crosslinker (1)
- Water monitoring (1)
Feasibility of Parylene C for encapsulating piezoelectric actuators in active medical implants
(2023)
Parylene C is well-known as an encapsulation material for medical implants. Within the approach of miniaturization and automatization of a bone distractor, piezoelectric actuators were encapsulated with Parylene C. The stretchability of the polymer was investigated with respect to the encapsulation functionality of piezoelectric chips. We determined a linear yield strain of 1% of approximately 12-μm-thick Parylene C foil. Parylene C encapsulation withstands the mechanical stress of a minimum of 5×105 duty cycles by continuous actuation. The experiments demonstrate that elongation of the encapsulation on piezoelectric actuators and thus the elongation of Parylene C up to 0.8 mm are feasible.
Novel method for plasma etching of printed circuit boards as alternative for fluorocarbon gases
(2023)
Atomic Layer Deposition of Bioactive TiO2 Thin Films on Polyetheretherketone for Orthopedic Implants
(2021)
Passivated electrode side walls by atomic layer deposition on flexible polyimide based samples
(2020)
Light-addressed sub-μm electrodes for extracellular recording and stimulation of excitable cells
(2001)
Langzeitstabile Verkapselungsschichten mit integriertem Feuchtesensor für aktive Mikroimplantate
(2012)