Volltext-Downloads (blau) und Frontdoor-Views (grau)

Investigation of Rogowski Current Sensors for Appliances Classification in NILM

  • In this paper, the influence of current sensors of a NILM system is investigated. The current sensors of a classical inductive current transformer and a Rogowski coil are compared. To evaluate the actual influence on the NILM, measurements are performed with two measuring systems with different current sensors. With these measuring systems, 20 different consumers with 50 switch-on and switch-off cycles are measured in parallel. Besides, the influence of the sampling rate on the results of the NILM classification is evaluated. The classification is carried out with features normalized to the performance and without phase information, so only the signal waveform is used to differentiate the devices.

Export metadata

Additional Services

Search Google Scholar

Statistics

frontdoor_oas
Metadaten
Author:Pirmin HeldORCiDGND, Daniel Weißhaar, Djaffar Ould-Abdeslam, Dirk BenyoucefORCiDGND
DOI:https://doi.org/10.1109/CANDO-EPE51100.2020.9337802
ISBN:978-1-7281-8491-3
Parent Title (English):2020 IEEE 3rd International Conference and Workshop in Óbuda on Electrical and Power Engineering (CANDO-EPE), 18-19 November 2020, Budapest, Hungary
Publisher:IEEE
Document Type:Conference Proceeding
Language:English
Year of Completion:2020
Release Date:2024/01/30
Tag:Current measurement; Current transformers; Performance evaluation; Power engineering
First Page:27
Last Page:32
Open-Access-Status: Closed Access 
Licence (German):License LogoUrheberrechtlich geschützt